NYC DEP Water Connections & Backflow Prevention

Water Connection & Backflow Prevention Design for NYC DEP

Our experienced engineers design your water service connection and backflow prevention device (RPZ or double check valve), submit the application to the NYC Department of Environmental Protection, and support you until it's approved.

Starting at$1,200
Turnaround as fast as2 days
100+DEP water connections approved
100sof projects designed across NYC
Since 2018in MEP & fire protection engineering
All 5 boroughsManhattan, Brooklyn, Queens, Bronx, Staten Island
Services

Everything you need to submit to DEP

Residential, commercial and mixed-use projects of any size. Send us the job and we handle the design, the DEP submission, and support until approval.

Domestic Water Service Design

New and upgraded water service connection drawings, ready for DEP review.

Fire Service Connections

Fire and combined service connection designs for sprinklered and standpipe buildings.

Backflow Prevention (RPZ) Plans

Backflow preventer plans for RPZ, double check valve (DCVA) and double check detector (DCDA) assemblies, cross-connection control reviews, and DEP exemptions.

Service & Meter Sizing

Fixture counts, water demand, pressure-loss calculations, and service and meter sizing.

DEP Site Connections

Site connection packages for new buildings and major alterations.

DEP Filing & Approval Support

We submit the application to DEP, answer any comments, resubmit, and support you until the job is approved.

We handle: Backflow preventionBackflow preventer plansRPZ (reduced pressure zone) assemblies Double check valve assemblies (DCVA)Double check detector assemblies (DCDA) Cross-connection controlDEP backflow approvals & exemptions Water service connectionsTap & wet connectionsFire & combined services Water meter sizingDEP application filing
See Our Design

A typical water connection, in 3D

A combined 2-1/2" water service with a fire sprinkler take-off: the City main, link seal through the foundation, DEP water meter assembly in the cellar, and an RPZ with an air-gap drain on the first floor. Drag to rotate.

Domestic water Fire sprinkler RPZ Meter
Drag to rotate

The 3D model can't be shown in this browser.

Why RPZ NYC

Work with a focused firm that specializes in one thing

General engineering firms juggle dozens of project types. DEP water connections and RPZ designs are our core work every day, and that focus is your advantage.

  • We know what DEP expects. We prepare these filings every day, so your package goes in complete and correct.
  • Fast. Turnaround as fast as 2 days keeps your permits and schedule on track.
  • Competitive fees. Flat pricing starting at $1,200, with volume pricing for repeat clients.
  • Experienced engineers. Hundreds of projects designed, and familiar with the requirements of every building type.
Simple Pricing
$1,200 starting price

Flat fee per water connection, quoted up front. No surprises.

  • Turnaround as fast as 2 days
  • We submit to DEP and support you until approval
  • Volume rates for contractors, plumbers and expeditors
  • One point of contact for all your jobs
Get My Quote
How It Works

Four simple steps

No back and forth. Send us what you have and we take it from there.

Send the job

Fill out the quote form with the address and project details, plus the documents you have.

Get a flat quote

You get a clear flat fee and a delivery date, usually the same day.

We design

Our engineers prepare the drawings and calculations to DEP requirements.

We submit & support

We submit the application to DEP and support you, including any DEP comments, until it's approved.

What We Need From You

What we need to get started

Send us these documents and we take care of the rest: design, DEP submission, and support until approval. Having them ready lets us deliver in as little as 2 days.

  • A new survey or proof of the street water main sizeShows the size and location of the City main at your property
  • Location of the RPZ / backflow preventer (BFP)Where you plan to install the device in the building
  • CAD files of the architectural backgroundFloor plans we can use as the base for our drawings
  • DOB-approved PL and/or SP drawingsPlumbing (PL) plans, site plan (SP), or both if applicable
  • DOB-approved zoning analysisThe approved zoning analysis for the project
  • DEP fee checkThe check is sent by the client directly to DEP
Missing some of these?Contact us anyway. Our team will tell you what's needed and help you get it.
Contact Our Team
About RPZ NYC

A New York City firm focused on getting your water connection approved

RPZ NYC designs water service connections and RPZ / backflow prevention systems for submission to the NYC Department of Environmental Protection. We know DEP's requirements, its forms and what its reviewers look for.

Our experienced engineers have been designing mechanical, plumbing and fire protection systems in New York City since 2018. We have worked on hundreds of projects, with more than 100 DEP water connections approved, and we are familiar with the requirements of every type of building.

We work with property owners, contractors, plumbers, expeditors and architects in all five boroughs. Our principles are simple: deliver on the date we promise, keep our fees fair, and make every drawing clear and dependable.

Residential1–3 family homes, multifamily and walk-ups
CommercialRetail, office, restaurants, clinics and industrial
Mixed-Use & New BuildingsGround-up developments and conversions
Alterations & UpgradesService upgrades, meter changes, new fire service
Need More Design Services?

Full engineering services under one roof

Water connections are our focus, but our engineers also design complete building systems. Tell us what you need and we'll send you a quote.

Plumbing

  • Domestic water
  • Sanitary systems
  • Gas system design
  • Storm drainage
  • DEP site connections
  • DEP water connections
  • Backflow prevention devices & RPZ
  • Low Impact Development (LID)
  • Weapons of Mass Destruction (WMD) design
  • Medical gas piping
  • Site distribution

Fire Protection

  • Sprinkler systems (wet & dry)
  • Fire pumps
  • Standpipes
  • Inergen clean-agent suppression
  • Backflow prevention devices & RPZ
  • Smoke control

Mechanical

  • Heating & boiler plants
  • Air conditioning
  • Cooling & chiller plants
  • Ventilation, exhaust & make-up air
  • Building automation systems
  • Duct design & energy-saving solutions
  • Clean rooms & data centers
  • Restaurant & kitchen hood design
  • Geothermal (ground-source) heat pumps
  • Title-24 reports
  • Manual J, S, D & N reports

Electrical

  • Building power distribution
  • Lighting & emergency lighting
  • Control systems
  • Fire detection & fire alarm systems
  • Site distribution systems
  • UPS power distribution

Architectural & Structural

  • Architectural consulting
  • Structural design
  • Residential & commercial projects
  • Post-design support

Inspections, Energy & LEED

  • NYC Special Inspections
  • Energy audits
  • LEED consulting

Request a Quote

Free Quote

Get a price today

Tell us about the project and we'll reply with a flat fee and delivery date. Water connections start at $1,200.

You can attach your survey, CAD files and DOB-approved plans in the email that opens next.

FAQ

Frequently asked questions about NYC DEP water connections and RPZs

Filing with DEP
Why do I need to file a water connection application with DEP?

NYC DEP controls every connection to the City water main. A new tap, wet connection, service upgrade, or repair/relay of a water service line needs a DEP permit under the City's water rules (Title 15 RCNY, Chapter 20). DEP reviews the application to confirm that the service is sized correctly for your building and that the public water supply is protected from backflow.

Properties that pose a backflow hazard also need a cross-connection control approval, or an exemption, before DEP will issue the tap permit. Under New York State law, those properties must install, maintain and test a backflow prevention device. Skipping it can lead to fines or a shut-off of water service.

What do I need to submit with my application to DEP?
  • Backflow plans prepared, signed and sealed by a Professional Engineer or Registered Architect, with DEP's Application for Approval of Backflow Prevention Assemblies. Some double check and one-domestic-service cases can use DEP's self-certification or exemption forms instead.
  • Site plan showing the City main, all fire and domestic service lines, the meter and the device location.
  • Plumbing floor plan and riser diagram showing the device, drains, clearances and nearby equipment.
  • Engineering data: a fixture count, water demand, service and meter sizes, and pressures before and after the device.
  • For the tap or wet connection permit (filed by your Licensed Master Plumber): the DOB-approved site plan, the plumbing riser diagram, Schedule B, and the DEP backflow approval or exemption letter.
  • After installation: an initial test report, signed by the certified tester, the plumber and the PE/RA, is due to DEP within 30 days. Annual tests are required after that.

We prepare the complete package, submit the application to DEP, and support you until it's approved. Your part is to send us the documents listed in What We Need From You and to send the DEP fee check directly to DEP.

Do I also need Department of Buildings (DOB) approval?

Yes, in most cases. DEP's tap and wet connection permits require a DOB-approved site plan and plumbing riser diagram, and your Licensed Master Plumber files the plumbing work with DOB. For fire services, DOB determines the size and type of the connection, and a combined domestic and fire service needs DOB approval.

How long is a DEP cross-connection approval valid?

A DEP cross-connection control review is valid for two years from the date of approval. If the device isn't installed in that time, the plans may need to be resubmitted.

What happens if I don't install a required backflow device?

New York State law requires certain properties to install, maintain and test backflow prevention devices. A property that doesn't comply can be fined or have its water service disconnected, and DEP won't issue a new tap permit for a hazardous property without a cross-connection approval.

RPZ & backflow prevention
What is a cross-connection, and what is backflow?

A cross-connection is any point where the drinking water system could connect to a non-drinking source, such as a boiler, a sprinkler or irrigation system, or chemical equipment. Backflow is water flowing the wrong way through that connection, back toward the City main.

It happens in two ways: backsiphonage, when the supply pressure drops (for example, during a water main break or firefighting), and backpressure, when pressure inside the building is higher than the supply (for example, from pumps or boilers). A backflow prevention device stops both.

Why should I use an RPZ and not a double check valve?

Both devices stop water from flowing backward into the City main, but an RPZ (reduced pressure zone assembly) gives a higher level of protection. Between its two check valves is a relief valve. If either check valve leaks, the relief valve opens and discharges water, so contaminated water cannot get back into the main even when a check valve fails. The discharge also tells you right away that the device needs service.

A double check valve assembly has no relief valve, so a leaking check can go unnoticed until the annual test. That is why an RPZ (or an air gap) is required wherever backflow could carry substances hazardous to health. A double check is accepted only for lower-hazard conditions.

When do I need an RPZ, and when is a double check valve enough?

It depends on the degree of hazard at your property:

  • RPZ (high hazard): where backflow could contaminate the water with something harmful. Examples include hospitals, medical and dental offices, laboratories, car washes, laundries and dry cleaners, auto repair shops, buildings with chemically treated boilers or cooling systems, irrigation with chemical injection, and properties with a well or other water source.
  • Double check valve (lower hazard): where backflow would be objectionable but not a health hazard. Examples include many fire sprinkler systems without chemical additives, and irrigation without chemicals.
  • Device required unless exempt: DEP also requires a device at properties such as premises with multiple service lines, roof tanks, swimming pools, schools, nursing homes and commercial kitchens, unless DEP grants an exemption.

Our engineers assess your building using DEP's Backflow Prevention Risk Assessment Guide and specify the correct device, or file for an exemption where one applies.

Do I need an RPZ for my fire sprinkler system?

Not always. Many fire sprinkler and standpipe services without chemical additives can be protected by a double check (detector) assembly. An RPZ-type device is needed when the fire system poses a health hazard, for example when it contains antifreeze or other chemicals. Our engineer reviews the fire system and specifies the right assembly.

Does a 1–2 family home need a backflow device?

A typical home with one domestic service and no special hazards usually doesn't, and DEP has an exemption form for facilities with one domestic service only. A device may be required if the home has, for example, in-ground irrigation, a well or another water source, or equipment that uses chemicals. We'll check your property and tell you.

Why can't I sometimes put my RPZ or double check valve in the basement or cellar?
  • Flooding from the relief valve: an RPZ's relief valve can discharge a lot of water if it fails. Below grade, the room needs a gravity drain sized for the full relief flow, or another approved safeguard such as sump pumps on emergency power, water-level alarms, or enough floor volume to hold the discharge. Many cellars don't have this.
  • Flood zones: an RPZ should be at least 1 foot above the 100-year flood elevation. In many NYC flood-zone buildings, the cellar is below that level.
  • Clearances: the device must sit at a testable height, generally 30 to 60 inches to its centerline, with at least 12 inches clear above and 30 inches in front. An RPZ's relief valve must be at least 18 inches above the floor. Low cellar ceilings or tight spaces may not fit.
  • Protection and access: the device must be protected from freezing, kept away from electrical panels, and easy to reach for the annual test.

A double check valve can generally go below grade. RPZ locations are stricter. When the cellar doesn't work, our engineer finds a compliant location, such as the first floor or a heated enclosure outside.

Who installs and tests the RPZ?

After DEP approves the plans, a Licensed Master Plumber installs the device. A certified backflow tester then tests it, and the initial test report, signed by the tester, the plumber and the PE/RA, goes to DEP within 30 days. After that, the device must be tested every year and after any repair or replacement.

Design & engineering
When do I need two separate pipes from the street main to the building?

It depends on the building. In general, DEP requires a separate tap and service connection for each building. Whether the building needs separate domestic and fire services, or can use one combined service, depends on its size and height, its sprinkler and standpipe systems, its water demand, and Department of Buildings requirements. DOB determines the size and type of fire services, and a combined service needs DOB approval.

Our engineer reviews your building and determines whether one connection to the street is enough or more than one is required.

What engineering calculations do I need on the plans?
  • Fixture count and water demand: a fixture-unit count for the whole building, converted to peak demand in gallons per minute.
  • Service and tap sizing: the size of the service pipe and tap needed to meet that demand, per DEP sizing tables and the plumbing code.
  • Meter sizing for the domestic, fire or combined service.
  • Pressure-loss calculations: the available pressure at the street main, minus losses through the tap, service pipe, meter and backflow device (from the manufacturer's head-loss data). This gives the pressure before and after the device.
  • Minimum pressure check: enough pressure at the highest or most remote fixture, and whether a booster pump is needed.
  • Fire demand for sprinkler and standpipe systems on fire or combined services.
Why do you need a survey or proof of the water main size?

The size and location of the City main determine what tap and service size the main can support and where the connection can be made. A recent survey, or other proof of the main size, lets our engineer design a connection DEP will accept. If you don't have one, contact us and we'll help you figure out what's needed.

Working with us
How much does a water connection or RPZ design cost?

Water connection designs start at $1,200. We charge a flat fee based on the project's size and type. Send us the address and basic details for a firm quote, usually the same day.

How fast can you deliver?

Turnaround is as fast as 2 days once we have the documents we need. Tell us your deadline on the quote form.

Do you submit the application to DEP?

Yes. We submit the application to DEP for you and support you until it's approved. The only thing the client sends to DEP is the fee check.

Do you handle DEP comments?

Yes. If DEP issues comments, we revise and resubmit the drawings until the job is approved.

What is backflow prevention, and do I need a backflow preventer?

Backflow prevention protects the City's drinking water by stopping water from flowing backward from a building into the main. NYC DEP requires a backflow preventer, either an RPZ (reduced pressure zone assembly) or a double check valve assembly, at many types of properties, depending on the degree of hazard. We assess your building, design the right backflow prevention device, and get it approved by DEP.

Do you work with contractors, plumbers and expeditors?

Yes. Most of our work comes from plumbers, contractors, expeditors and developers. Ask about volume pricing.

Which areas do you serve?

All five boroughs of New York City: Manhattan, Brooklyn, Queens, the Bronx and Staten Island.

Can you design other building systems too?

Yes. Our engineers also provide plumbing, fire protection, mechanical, electrical, architectural and structural design, NYC Special Inspections, energy audits and LEED consulting. See More Services.

These answers are general information based on NYC DEP and New York State Department of Health backflow and water service guidance. Requirements depend on your building and can change. Our engineers confirm what applies to your project.

Have a water connection to submit?

Flat fees starting at $1,200. Turnaround as fast as 2 days.

Get a Free Quote